-
Dec 11, 2018
Recently, a chemical plant in a recycling industrial zone in Jinzhou, China, exploded. Fortunately, no one was killed or injured. What's the matter? let's go and have a look. On December 7, a chemical company in Jinzhou Recycling Industrial Park exploded. From the picture, we can see that it is dark around us, and our hands cannot see the five fingers. We can see it is at night, but in the distanc...
-
Dec 05, 2018
Fluoroplastics are alkane polymers in which some or all of the hydrogen is substituted by fluorine. They are polytetrafluoroethylene (PTFE) (PTFE), perfluoroethylene-propylene -) (FEP) copolymer, perfluoroalkoxy-(PFA) resin, polychlorotrifluoroethylene (PCTFE), ethylene-chlorotrifluoroethylene copolymer (ECTFE), Ethylene tetrafluoroethylene (ETFE) copolymer, polyvinylidene fluoride. (PVDF) and (PV...
-
Oct 09, 2018
If you expect the magnetic pump to be safe, stable and fault-free, you must abide by the eight golden rules of the magnetic pump manufacturer's Tenglong pump valve advice. Because most magnetic pump plants are not going to tell you this in detail. 1. Prohibition of idling operation. As soon as the magnetic pump runs out of liquid, the sliding bearing of the pump cavity will lose lubrication and we...
-
Oct 22, 2018
A.The magnetic pump works by. The magnet pairs (n is an even number) are arranged and assembled on the inner and outer magnetic rotors of the magnetic actuator according to the law, so that the magnet parts are mutually formed into a fully coupled magnetic force system.The magnetic energy of the magnetic system is the lowest when the internal and external magnetic poles are opposite, i.e., the dis...
-
Oct 11, 2018
Magnetic pump is a kind of magnetic drive to achieve non-contact torque transmission so as to replace the static seal with the dynamic seal, so that the pump is completely leak-free. Because the pump shaft and the inner magnetic rotor are completely closed by the pump body and the isolation sleeve, the problem of "running, rising, dripping and leaking" is completely solved, and the hidden danger o...
-
Oct 11, 2018
The centrifugal chemical pump with specific speed ns of 130 and 150 is usually selected. The flow rate of the electric chemical pump should be 1.1 and 1.2 times of the rated flow of the chillers (1.1 for a single pump and 1.2 for two parallel pumps).The estimated loss per 100m pipe length is 5mH2O, pump head (mH2O): Hmax = P1 + P2 + 0.05L (1 + K). P1 is the water pressure drop of the evaporator of...
-
Oct 12, 2018
1. Requirements for fluorinated plastic centrifugal pumps after they have stopped operation. a. After the Fluorine Plastic Centrifugal Pump stops working, should close the pump the population valve, after waits for the pump to cool down then in turn closes the auxiliary system valve. b.High Temperature Magnetic Pumpshutdown should be in accordance with the provisions of the equipment technical doc...
-
Oct 11, 2018
Magnetic pump has all the characteristics of centrifugal pump, but there is no mechanical seal centrifugal pump shaft seal leakage. No leakage of magnetic pump put an end to the leakage of the shaft seal pump to the chemical process due to the leakage of the accident hidden trouble. Magnetic pump design, compact structure, less parts, less vulnerable parts, low failure rate. According to the big d...
-
Jun 14, 2018
Fluoroplastic Magnetic Pump is a new type of pump, which uses the principle of modern magnetics and the magnetic drive of permanent magnet to realize the non-contact transmission of torque, that is, when the motor drives the outer rotor (that is, the outer magnetic steel) assembly to rotate. The magnetic field through the isolation sleeve drives the inner rotor (I. E. inner magnetic steel) assembl...